Experience Inc. Jobs

Job Information

MIDDLE RIO GRANDE DEVELOPMENT Communications Coordinator (Carrizo Springs or Uvalde) in Carrizo Springs, Texas

Business hours of operation: Monday to Friday, 8:00 am to 5:00 pm. [[[DIVISION: PLANNING and OPERATIONS ]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"} [[SUPERVISOR: DIRECTOR OF 9-1-1/ HOMELAND SECURITY ]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"} Position Headquarters: TBD Carrizo Springs or Uvalde]{style="font-size:16px;"} [[[GENERAL DESCRIPTION ]{style="font-family:Calibri,sans-serif"}]{style="line-height:200%"}]{style="font-size:11pt"} [[[Act as technical and able to use professional test equipment in systematic and component level testing and use gained information for a complete diagnose of technical problems. ]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Duties and responsibilities ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Be experienced and able to use professional test equipment in systematic and component level testing and use gained information for a complete diagnose of technical problems. ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Have a thorough and practical knowledge of RF, analog and digital electronics theory. ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Be well experienced in the technical principals of microwave, multiplex, 2-way ratio, telephone key systems, and telephone PBX. ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Must stay abreast of [projects and operational requirements of the telecommunications users in MRGDC are to ensure that all communications needs are met adequately and economically within the scope of the projects. ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Have a thorough understanding of electronic theory and various communications systems and be able to communicate those understandings in laypersons terms. ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Have experience and the ability to install and test data channel interconnect equipment using data circuit universal test sets for measuring amplitude, delay and phase distortion. ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Experience and able to perform numerous administrative functions such as: RFPs, system test and licensing records, preventative maintenance reports, inventory maintenance, grant proposal writing, correspondence and letter writing and personal records such as time and expense reports. ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Have above average driving skills with an excellent driving history. Because equipment failures often occur during severe weather conditions and will not wait for conditions to improve. Also, considerable routine driving to cover bast areas will be necessary. ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[EDUCATION AND/OR EXPERIENCE ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Holds a General Radiotelephone Operator License. Minimum 3 Years of extensive and varied experience in the telecommunications technical field. ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"} [[[[Be experienced in the operation and theory of professional test equipm nt including: ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}

  • [[[[Spectrum Analyzers ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}
  • [[[[Data Test Sets ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}
  • [[[[RF and Signal Generators ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}
  • [[[[Cable Sweep Equipment ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}
  • [[[[Transmission Line Testers ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}
  • [[[[Oscilloscopes ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}
  • [[[[Frequency Counters ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}
  • [[[[Digital and Analog Volt Ohm Meters ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}
  • [[[[Frequency Level Meters ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}
  • [[[[Communications Service Monitors ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}
  • [[[[Power Meters ]{style="font-size:12.0pt"}]{style="font-family:Calibri,sans-serif"}]{style="line-height:normal"}]{style="font-size:11pt"}

[Closing date: Open Until Filled! EO Employer!]{style="font-size:16px;"}

DirectEmployers